FEATURES |
● UL safety approval.
● Standard type & High sensitivity type available.
● 2 Amps super miniature relay.
● Conforms to FCC rules & regulation part 68.
● Surge strength: 1500 VAC.
● 1 Form C (SPDT) contact.
● Nominal power 200mW~360mW.
● Operating power 110mW~200mW.
● DIL pitch terminal.
● Washable Type (ultrasonic cleaning is not recommended) |
|
|
|
|
|
UL FILE NO:E162117
TUV FILE NO:
CE DECLARATION OF CONFORMITY
CQC FILE NO:
|
|
|
ORDERING INFORMATION |
946 |
H |
- |
1C |
12 |
D |
- |
F |
|
|
|
|
|
|
|
1 |
2 |
|
3 |
4 |
5 |
|
6 |
|
|
|
|
|
|
|
|
1 |
Model Number |
2 |
Coil Sensitivity
Nil = Standard Type
H = High Sensitive Type
|
3 |
Contact Arrangement
1C = 1 Form C (SPDT) |
4 |
Coil Voltage
3-24V |
5 |
Coil Type
D:DC |
6 |
Terminal arrangement
Nil = General Type
F = Movable contact terminal & Coil terminal at one Side
|
|
|
COIL RATINGS (at 20℃) |
COIL
TYPE |
Coil Nominal
Voltage (V) |
Coil
Resistance
(Ω+-10%) |
Pick-Up
Voltage (V)
<= |
Drop-Out
Voltage (V)
>= |
Nominal
Current
(mA) |
DC High Sensitive Coils |
3 |
45 |
2.25 |
0.3 |
66.7 |
5 |
125 |
3.75 |
0.5 |
40 |
6 |
180 |
4.5 |
0.6 |
33.3 |
9 |
405 |
6.75 |
0.9 |
22.2 |
12 |
720 |
9 |
1.2 |
16.7 |
24 |
2880 |
18 |
2.4 |
8.3 |
DC Standard Coils |
3 |
25 |
2.25 |
0.3 |
120 |
5 |
70 |
3.75 |
0.5 |
71.4 |
6 |
100 |
4.5 |
0.6 |
60 |
9 |
220 |
6.75 |
0.9 |
40.9 |
12 |
400 |
9 |
1.2 |
30 |
24 |
1600 |
18 |
2.4 |
15 |
|
|
* Max Continuous Voltage at 20℃:? 130% of Coil Nominal Voltage. |
CONTACT RATINGS |
●Contact Arrangement |
|
●Max. Switching Power |
|
|
●Max. Switching Voltage |
|
● Max. Switching Current |
|
|
●Contact Resistance |
|
●Resistive Load |
|
|
●Contact Material |
|
●Inductive Load |
|
●Pilot Duty Load |
|
●Rating Load |
|
●Tv Rating |
|
●Remark |
|
|
|
CHARACTERISTICS |
●Electrical Life |
100,000 |
●Mechanical Life |
10,000,000 |
●Initial Insulation Resistance |
Min. 100MΩ 500VDC |
●Contact Resistance (Initial) |
≤100mΩ |
●Operate Time |
≤6ms |
●Release Time |
≤3ms |
●Initial Dielectric Strength |
50/60Hz 500VAC 1 min. (between open contacts)50/60Hz 500VAC 1 min. (between contacts and coil)
|
● Vibration Resistance |
Malfunction: 10 to 55Hz at Double Amplitude of 1.5mm Destructive: 10 to 55Hz at Double Amplitude of 1.5mm
|
●Shock Resistance |
Malfunction: 10G (11ms) / Destructive: 100G (6ms) |
●Ambient Temperature |
-20℃~+40℃ |
●Relative Humidity |
85% at 40℃ |
●Unit Weight |
Approx. 3g |
●Remark |
|
|
|